Skip to main content

VA-Hydro Legionella Liquidation - Eliminating Legionella in Drinking Water


Legionella in water supply is a real danger. The causes of Legionnaires' disease are feared and must be eliminated as soon as possible. Legionella in drinking water is not primarily about the contaminated water, but rather about the aerosols that, when inhaled, pose a health risk.

The danger of Legionella

The highly toxic bacteria of the species Legionella pneumophila initiate harmful metabolic processes. They are capable of activating enzymatic processes that negatively affect cellular processes and burden the entire organism. Severe respiratory illnesses threaten not only seniors and immunocompromised individuals, although they are the main risk group. The problem of increased Legionella contamination has become an increasingly serious issue over the past 20 years. Outdated pipelines, contaminated water catchment tanks, and inadequately maintained air conditioning systems with corresponding cooling towers provide the bacteria with the environment in which they can multiply unchecked.

Legionella can be found in waters around the world. They become dangerous when they exceed a certain concentration. In Germany, the limit is 100 Legionella per 100 milliliters of water. The cause of the proliferation is higher temperatures between 25 and 45 °C, which are found in water systems. Once the bacteria are in the system, they multiply at an uncontrolled rate. This point is particularly critical when the temperature is lowered as part of upcoming energy-saving measures.

Only at temperatures above 60 °C are the bacteria killed, and temperatures below 20 °C significantly inhibit their multiplication.

VA-Hydro - Legionella Liquidation for maximum protection

It is not the contaminated drinking water that is responsible for Legionella infection, but rather aerosols that enter the lungs through the airway. One particularly insidious aspect of Legionella in drinking water is their ability to rapidly spread through cells of the immune system while secreting virulence factors, some of which are extremely toxic and immediately exert their damaging influence. This causes their host cells to die immediately and activates breakdown processes.

The water quality is constantly monitored for Legionella. Restrictions may be imposed by authorities already at 100 CFU per 100 milliliters. Once the value reaches 10,000, the health department can impose a shower ban or even the closure of facilities such as swimming pools.
To counteract this, prophylaxis is practiced, often thermally, which requires a very high energy expenditure, or chemically, which can not only be harmful to the environment but also to health.

VA-Hydro eliminates Legionella contamination through physical means. The water from the raw water tank is treated in a bypass system and returned after filtration. In addition to Legionella, traces of fungi and algae spores are also effectively eliminated. This effectively prevents the danger of Legionella entering the treatment circuit through the drinking water. The entire filtration process is environmentally friendly and carried out by physical means. Chemical cleaning agents and thermal treatment processes, which require a lot of energy to heat the water to over 60°C, are now a thing of the past.

VA-Hydro Legionella Liquidation - Applications


The VA-Hydro by VISION AQUA® is already being used in heavy industry, breweries, and many other sectors because the system offers numerous advantages over chemical and thermal methods.

ühlturm als Anwendungsbereich für den VA-Hydro Legionellenfilter

Legionella eradication in cooling towers

With VA-Hydro, you can prevent biological contamination in cooling installations and cooling towers. Biofilms in the pipelines are broken down and subsequent algae and biofilm growth is prevented.
Reduce cleaning efforts and save costs for biocides.

Eien junge Frau springt in das Wasser von einem Schwimmbad

Legionella eradication in swimming pools

Ensure a legionella-free hot water supply in wet and shower areas with VA-Hydro. The system is particularly beneficial for swimming pools, as it can help you reduce your energy costs for water treatment and eliminate the need for chemical cleaning agents.

Eine Flasche wird gereinigt als Anwendungsbereich für den VA-Hydro Legionellenfilter

Legionella eradication in cleaning systems

Improve the washing and cleaning effect in industrial applications of any kind with VA-Hydro. With the treated water, you also extend the service life of lye, cooling lubricants, and cleaning baths while eradicating Legionella.

Eine Sprinkleranlage in einem Bürogebäude, das mit dem Wasser des VA-Hydro Legionellenfilter betrieben wird

Legionella eradication in fire-fighting water

The water treated with VA-Hydro cleanses the piping systems of sprinkler systems from microorganisms and Legionella colonies. During a fire-fighting operation, Legionella cannot enter the respiratory tract via aerosols, thus eliminating any health risks.

Rechenzentrum in dem ein Laptop an Servern angeschlossen ist

Legionella eradication in data centers

Cooling is one of the biggest energy consumers in data centers. With VA-Hydro, you can use treated water for water cooling, reduce your energy costs and expenses for biocides, and make your data center sustainable and environmentally friendly.

Ein Springbrunnen im Grünen, der mit dem Wasser aus dem VA-Hydro LEgionellenfilter betrieben wird

Legionella eradication in irrigation systems

The VA-Hydro removes not only Legionella, but also algae from the water, making it possible to eliminate unsightly algae growth in irrigation systems. Thanks to the hygienically stable water, there is no risk of re-contamination, since only treated water flows through the pipelines.

VA-Hydro - Introduction in the swimming pool sector - german

The VA-Hydro from VISION AQUA® is the perfect solution for a clean and legionella-free swimming pool. Without the use of chemical cleaning agents, Legionella is effectively removed from the water. The VA-Hydro also serves as a prevention in the treatment of swimming pool water.

Ensure Legionella prevention with our VA-Hydro

We look forward to hearing from you and providing comprehensive advice on the perfect filtration solution tailored to your specific needs. The VA-Hydro eliminates Legionella without the use of biocides, making it a sustainable and environmentally-friendly solution. Installing our VA-Hydro contributes to a green environmental balance and actively supports environmental protection efforts.
For new construction projects, we recommend including VA-Hydro installation in the planning phase. With us, you are in safe hands and need not worry about Legionella. Our powerful VA-Hydro accompanies you into a safe and germ-free future.

VA-Hydro Legionella elimination without pump

With a production capacity of up to 51 m3/h for the largest VA-Hydro, there is always enough water available for easily operating large industrial applications such as cleaning systems, swimming pools, cooling towers, etc.
The VA-Hydro is delivered without a pump for flow rates starting from 4 m3/h. A suitable pump for the required water flow rate can be found on the detail page of the selected system.

VA-Hydro - capacity 41 - 51 m³/h, without pump
Water and fluid treatment system for the prevention and reduction of biological and organic germ contamination in drinking water as well as in industrial and process water and all water-carrying pipes and parts.Consisting of:Reaction chamber, reinforced hoses, Y-piece, guide/discharge frame with internal thread, depth adjustment pin, ball valve: components are all made of V2A stainless steelViewing tube made of V2A and DURAN glassInlet pressure gauge (0…+16 bar): shock-absorbing made of V2AVacuum gauge (-1.0…+3.0 bar): shock-absorbing made of V2AHousing with lockable opening flap made of V2ATechnical specifications:Output: up to 41 - 51 m³/hWeight: approx. 82 kgDimensions [mm]: W (550) x H (1080) x D (660)Max. test pressure: 16 barMax. working pressure: 16 barMax. negative pressure nozzle (rel.): - 0.99 barMaterial: VA, DIN 1.4301-1.4408 (or equivalent)Connection: inlet 1 ½ ", outlet 1 ½ "Safety and quality:The water-carrying components installed in the product microbiological water treatment system (VA-Hydro) are tested materials according to DIN 1.4571. They meet the DIN DVGW requirements and are suitable for installation in drinking water and cooling water systems. The manufacturer's declaration can be found as an appendix in the supplementary sheet.
VA-Hydro - capacity 32 - 43 m³/h, without pump
Water and fluid treatment system for the prevention and reduction of biological and organic germ contamination in drinking water as well as in industrial and process water and all water-carrying pipes and parts.Consisting of:Reaction chamber, reinforced hoses, Y-piece, guide/discharge frame with internal thread, depth adjustment pin, ball valve: components are all made of V2A stainless steelViewing tube made of V2A and DURAN glassInlet pressure gauge (0…+16 bar): shock-absorbing made of V2AVacuum gauge (-1.0…+3.0 bar): shock-absorbing made of V2AHousing with lockable opening flap made of V2ATechnical specifications:Output: up to 32 - 43 m³/hWeight: approx. 82 kgDimensions [mm]: W (550) x H (1080) x D (660)Max. test pressure: 16 barMax. working pressure: 16 barMax. negative pressure nozzle (rel.): - 0.99 barMaterial: VA, DIN 1.4301-1.4408 (or equivalent)Connection: inlet 1 ½ ", outlet 1 ½ "Safety and quality:The water-carrying components installed in the product microbiological water treatment system (VA-Hydro) are tested materials according to DIN 1.4571. They meet the DIN DVGW requirements and are suitable for installation in drinking water and cooling water systems. The manufacturer's declaration can be found as an appendix in the supplementary sheet.
VA-Hydro - capacity 24 - 33 m³/h, without pump
Water and fluid treatment system for the prevention and reduction of biological and organic germ contamination in drinking water as well as in industrial and process water and all water-carrying pipes and parts.Consisting of:Reaction chamber, reinforced hoses, Y-piece, guide/discharge frame with internal thread, depth adjustment pin, ball valve: components are all made of V2A stainless steelViewing tube made of V2A and DURAN glassInlet pressure gauge (0…+16 bar): shock-absorbing made of V2AVacuum gauge (-1.0…+3.0 bar): shock-absorbing made of V2AHousing with lockable opening flap made of V2ATechnical specifications:Output: up to 24 - 33 m³/hWeight: approx. 80 kgDimensions [mm]: W (550) x H (1080) x D (660)Max. test pressure: 16 barMax. working pressure: 16 barMax. negative pressure nozzle (rel.): - 0.99 barMaterial: VA, DIN 1.4301-1.4408 (or equivalent)Connection: inlet 1 ½ ", outlet 1 ½ "Safety and quality:The water-carrying components installed in the product microbiological water treatment system (VA-Hydro) are tested materials according to DIN 1.4571. They meet the DIN DVGW requirements and are suitable for installation in drinking water and cooling water systems. The manufacturer's declaration can be found as an appendix in the supplementary sheet.
VA-Hydro - capacity 15 - 24 m³/h, without pump
Water and fluid treatment system for the prevention and reduction of biological and organic germ contamination in drinking water as well as in industrial and process water and all water-carrying pipes and parts.Consisting of:Reaction chamber, reinforced hoses, Y-piece, guide/discharge frame with internal thread, depth adjustment pin, ball valve: components are all made of V2A stainless steelViewing tube made of V2A and DURAN glassInlet pressure gauge (0…+16 bar): shock-absorbing made of V2AVacuum gauge (-1.0…+3.0 bar): shock-absorbing made of V2AHousing with lockable opening flap made of V2ATechnical specifications:Output: up to 15 - 24 m³/hWeight: approx. 80 kgDimensions [mm]: W (550) x H (1080) x D (660)Max. test pressure: 16 barMax. working pressure: 16 barMax. negative pressure nozzle (rel.): - 0.99 barMaterial: VA, DIN 1.4301-1.4408 (or equivalent)Connection: inlet 1 ½ ", outlet 1 ½ "Safety and quality:The water-carrying components installed in the product microbiological water treatment system (VA-Hydro) are tested materials according to DIN 1.4571. They meet the DIN DVGW requirements and are suitable for installation in drinking water and cooling water systems. The manufacturer's declaration can be found as an appendix in the supplementary sheet.
VA-Hydro - capacity 9 - 15 m³/h, without pump
Water and fluid treatment system for the prevention and reduction of biological and organic germ contamination in drinking water as well as in industrial and process water and all water-carrying pipes and parts.Consisting of:Reaction chamber, reinforced hoses, Y-piece, guide/discharge frame with internal thread, depth adjustment pin, ball valve: components are all made of V2A stainless steelViewing tube made of V2A and DURAN glassInlet pressure gauge (0…+16 bar): shock-absorbing made of V2AVacuum gauge (-1.0…+3.0 bar): shock-absorbing made of V2AHousing with lockable opening flap made of V2ATechnical specifications:Output: up to 9 - 15 m³/hWeight: approx. 80 kgDimensions [mm]: W (550) x H (1080) x D (660)Max. test pressure: 16 barMax. working pressure: 16 barMax. negative pressure nozzle (rel.): - 0.99 barMaterial: VA, DIN 1.4301-1.4408 (or equivalent)Connection: inlet 1 ½ ", outlet 1 ½ "Safety and quality:The water-carrying components installed in the product microbiological water treatment system (VA-Hydro) are tested materials according to DIN 1.4571. They meet the DIN DVGW requirements and are suitable for installation in drinking water and cooling water systems. The manufacturer's declaration can be found as an appendix in the supplementary sheet.
VA-Hydro - capacity 8 - 11 m³/h, without pump
Water and fluid treatment system for the prevention and reduction of biological and organic germ contamination in drinking water as well as in industrial and process water and all water-carrying pipes and parts.Consisting of:Reaction chamber, reinforced hoses, Y-piece, guide/discharge frame with internal thread, depth adjustment pin, ball valve: components are all made of V2A stainless steelViewing tube made of V2A and DURAN glassInlet pressure gauge (0…+16 bar): shock-absorbing made of V2AVacuum gauge (-1.0…+3.0 bar): shock-absorbing made of V2AHousing with lockable opening flap made of V2ATechnical specifications:Output: up to 8 - 11 m³/hWeight: approx. 78 kgDimensions [mm]: W (550) x H (1080) x D (660)Max. test pressure: 16 barMax. working pressure: 16 barMax. negative pressure nozzle (rel.): - 0.99 barMaterial: VA, DIN 1.4301-1.4408 (or equivalent)Connection: inlet 1 ½ ", outlet 1 ½ "Safety and quality:The water-carrying components installed in the product microbiological water treatment system (VA-Hydro) are tested materials according to DIN 1.4571. They meet the DIN DVGW requirements and are suitable for installation in drinking water and cooling water systems. The manufacturer's declaration can be found as an appendix in the supplementary sheet.
VA-Hydro - capacity 6 - 8 m³/h, without pump
Water and fluid treatment system for the prevention and reduction of biological and organic germ contamination in drinking water as well as in industrial and process water and all water-carrying pipes and parts.Consisting of:Reaction chamber, reinforced hoses, Y-piece, guide/discharge frame with internal thread, depth adjustment pin, ball valve: components are all made of V2A stainless steelViewing tube made of V2A and DURAN glassInlet pressure gauge (0…+16 bar): shock-absorbing made of V2AVacuum gauge (-1.0…+3.0 bar): shock-absorbing made of V2AHousing with lockable opening flap made of V2ATechnical specifications:Output: up to 6 - 8 m³/hWeight: approx. 78 kgDimensions [mm]: W (550) x H (1080) x D (660)Max. test pressure: 16 barMax. working pressure: 16 barMax. negative pressure nozzle (rel.): - 0.99 barMaterial: VA, DIN 1.4301-1.4408 (or equivalent)Connection: inlet 1 ½ ", outlet 1 ½ "Safety and quality:The water-carrying components installed in the product microbiological water treatment system (VA-Hydro) are tested materials according to DIN 1.4571. They meet the DIN DVGW requirements and are suitable for installation in drinking water and cooling water systems. The manufacturer's declaration can be found as an appendix in the supplementary sheet.
VA-Hydro - capacity 4 - 6 m³/h, without pump
Water and fluid treatment system for the prevention and reduction of biological and organic germ contamination in drinking water as well as in industrial and process water and all water-carrying pipes and parts.Consisting of:Reaction chamber, reinforced hoses, Y-piece, guide/discharge frame with internal thread, depth adjustment pin, ball valve: components are all made of V2A stainless steelViewing tube made of V2A and DURAN glassInlet pressure gauge (0…+16 bar): shock-absorbing made of V2AVacuum gauge (-1.0…+3.0 bar): shock-absorbing made of V2AHousing with lockable opening flap made of V2ATechnical specifications:Output: up to 4 - 6 m³/hWeight: approx. 78 kgDimensions [mm]: W (550) x H (1080) x D (660)Max. test pressure: 16 barMax. working pressure: 16 barMax. negative pressure nozzle (rel.): - 0.99 barMaterial: VA, DIN 1.4301-1.4408 (or equivalent)Connection: inlet 1 ½ ", outlet 1 ½ "Safety and quality:The water-carrying components installed in the product microbiological water treatment system (VA-Hydro) are tested materials according to DIN 1.4571. They meet the DIN DVGW requirements and are suitable for installation in drinking water and cooling water systems. The manufacturer's declaration can be found as an appendix in the supplementary sheet.

VA-Hydro Legionella Elimination - compact including pump

The VA-Hydro is ideal for smaller applications in its compact version. The corresponding pump for the compact version has a capacity of up to 2.5 m3/h to direct the water into the system for treatment.
For applications with non-pressurized containers for water storage, the VA-Hydro is available as an open circuit. If you use pressure vessels for water storage, the VA-Hydro is the best choice for closed circuits.

VA-Hydro - (closed cycle) capacity 0,1 - 2,5 m³/h, incl. pump
Water and fluid treatment system for the prevention and reduction of biological and organic germ contamination in drinking water as well as in industrial and process water and all water-carrying pipes and parts.Consisting of:Reaction chamber, reinforced hoses, Y-piece, guide/discharge frame with internal thread, depth adjustment pin, ball valve: components are all made of V2A stainless steelViewing tube made of V2A and DURAN glassInlet pressure gauge (0…+16 bar): shock-absorbing made of V2AVacuum gauge (-1.0…+3.0 bar): shock-absorbing made of V2AHousing with lockable opening flap made of V2ATechnical specifications:Output: up to 0,1 - 2,5 m³/hWeight: approx. 95 kgDimensions [mm]: W (550) x H (960) x D (550)Max. test pressure: 16 barMax. working pressure: 16 barMax. negative pressure nozzle (rel.): - 0.99 barMaterial: VA, DIN 1.4301-1.4408 (or equivalent)Connection: inlet 1 ¼ ", outlet 1 ¼ " (optional depending on the location)Safety and quality:The water-carrying components installed in the product microbiological water treatment system (VA-Hydro) are tested materials according to DIN 1.4571. They meet the DIN DVGW requirements and are suitable for installation in drinking water and cooling water systems. The manufacturer's declaration can be found as an appendix in the supplementary sheet.
VA-Hydro - (open cycle) capacity 0,1 - 2,5 m³/h, incl. pump
Water and fluid treatment system for the prevention and reduction of biological and organic germ contamination in drinking water as well as in industrial and process water and all water-carrying pipes and parts.Consisting of:Reaction chamber, reinforced hoses, Y-piece, guide/discharge frame with internal thread, depth adjustment pin, ball valve: components are all made of V2A stainless steelViewing tube made of V2A and DURAN glassInlet pressure gauge (0…+16 bar): shock-absorbing made of V2AVacuum gauge (-1.0…+3.0 bar): shock-absorbing made of V2AHousing with lockable opening flap made of V2ATechnical specifications:Output: up to 0,1 - 2,5 m³/hWeight: approx. 95 kgDimensions [mm]: W (550) x H (960) x D (550)Max. test pressure: 16 barMax. working pressure: 16 barMax. negative pressure nozzle (rel.): - 0.99 barMaterial: VA, DIN 1.4301-1.4408 (or equivalent)Connection: inlet 1 ¼ ", outlet 1 ¼ " (optional depending on the location)Safety and quality:The water-carrying components installed in the product microbiological water treatment system (VA-Hydro) are tested materials according to DIN 1.4571. They meet the DIN DVGW requirements and are suitable for installation in drinking water and cooling water systems. The manufacturer's declaration can be found as an appendix in the supplementary sheet.

Subscribe to our newsletter

Subscribe to our newsletter and always stay up to date!

 You can unsubscribe from the newsletter at any time. You will find the unsubscribe link at the end of every newsletter message. Of course, your data is transmitted via a secure connection, treated confidentially, and not shared. Information about data processing can be found in our data protection declaration.

VISION AQUA Reverse Osmosis Systems and Water Filter Shipping Information and Payment Methods